Home > Products > Liquid Level > 5700 Series Guided Wave Radar Level Device
 > Specifications
 
Function Level, distance and volume measurement of liquids.
Measuring Range Flexible probe: to 78 ft
Deadband:
    Top: 15.8 in Dielectric < 10, 11.8 in Dielectric > 10
    Bottom: 10.25 in
Counter Weight Dia.: 1.575 in: length 10.25 in (Weight is tapped with ½" - 13 to allow tethering or anchoring)
Accuracy +/- 0.6 in
Repeatability 0.04 in
Dielectric Constant > 2.3
Probe Materials Flexible cable 316SS
Operating Pressure 232 psi
Operating Temperature -22° to 194° F
Ambient Temperature -22° to 131° F
Connection 1.5" MNPT
Protection Category IP66; Nema 4X
Power Supply 24VDC (18 to 35VDC)
Output 4/20mA current loop into max. of 750 Ohms
Communication HART protocol
Approvals CE
Weight Without probe 4.4lbs (2Kgs)
Materials of Construction Housing: Aluminum with white epoxy coating
Cable and Weight: 316SS
Gaskets: Buna N
ELECTRICAL CONNECTION
Terminals Wire cross section max AWG 16 (1.5mm)
Cable Entries 1 x M16 x 1.5 (with standard cable gland: cable clamping area = 3.5-8mm)
ELECTRICAL SIGNAL OUTPUT
Electrical Connection Two wire
Power Supply 18 to 35 VDC
Current Output 4/20mA
Ambient Temperature -22° to 131° F
Protection Category to EN 60529 / IEC 529 IP66, Nema 4X